The external steam generator requires a space measuring:
Width: 80 centimeters
Height: 100 centimeters
Depth: 30 centimeters
Make sure the generator is accessible from the front
At the location of the external steam generator, the following is required:
– Cold water connection
– Heat-resistant trap
– Electrical wiring behind a circuit breaker
– Any power outlets for additional modules
– Copper steam pipe, running from the steam generator to the steam bath
Please make sure that the steam line:
– never has sharp turns
– always slopes toward the steam inlet and does not form a pocket
– is no longer than 4 meters
– about 17 centimeters from the floor
– never comes out from under a steam bench
– and is well insulated
Check the manual for the minimum diameter of the steam line. A steam line that is too narrow will cause resistance in the line.
Make sure that the odorant line
It must always be installed in the downward direction of the steam line. This prevents any fragrance from flowing back into the steam generator.