€ 3.308,00 VAT incl.
The steam generator Cleo Steam One is a high-quality steam generator for home and semi-professional use. The Cleo Steam One is installed outside the steam room in. For installation inside the steam room, the BackWall Steam One is offered; see here For more information.
The Cleo Steam One steam technology is available with the powers below.
The following options can be ordered with the Cleo Steam One:
In the manual you will find all the important information regarding this product. You can find the installation manual:
Click here: Steam One installation manual
Click here: Steam One user manual
SPACE ABOVE THE CABIN
For connection of venting and lighting, add at least 150 mm to the net height dimension.
FLOOR & DRAIN
A small recess is kept under the steam room door to allow air to be drawn in. Care
That the floor drains sufficiently to drain shower water. Advice: under the glass door, make a low something
In this way, condensation water from the door runs back into the cabin. For
protection of tiling, the drainage channel is preferably placed at the bottom of the steam inlet.
NATURAL VENTILATION
Provide venting in roof or high in cabin wall. Or natural or mechanical ventilation in a low
position. Do not place the vent above the steam inlet.
ELECTRICITY AND WATER
Steam generator power calculation: cabin length x width x height (max 220 cm) x 1.25 and that is
up to a cabin volume of 7.2 m3. Above this volume it is possible to order a slave generator
(3, or 6kW). When choosing power if there is a glass front, be sure not to round down.
For a steam generator of 3 kW a 230V connection is sufficient, from 4.5 kW onwards 400 V or 2x 230V is required.
required. Depending on the generator and lights selected, it must be determined whether the light will pass through the generator
controlled or whether a second power supply for the lights is necessary. We recommend
please about this. Dimensions of the generators apply to all powers; the steam pipe and built-in parts
are 28 mm. The following are needed at the generator site: water, heat-resistant siphon, working switch and electrical
power supply. Water pressure should be normal. With hard water, it is recommended to use a water softener for the
steam generator to be placed.
PIPE FROM THE GENERATOR
If an external steam generator is used then the steam line from generator to steam inlet may be
max. be 3.5 m. From the steam generator, the pipe must first rise (45 cm) and then slope to
down toward the steam inlet. The steam line should be insulated, bend bends - do not use
knees and make wide turns.
DIFFUSER NOZZLE
If fragrance dosing has been chosen: the connection piece should remain accessible and in the section
of the steam line to be mounted that runs downhill with a slope. This allows the odor
never get into the steam generator.
WARRANTY
All Cleopatra generators come standard with a 2-year manufacturer's warranty.
BUILDINGS
Cleopatra provides built-in parts for sensors, controls and steam inlet that third parties must work into walls and tiles. For information on dimensions and how these should be processed, please read the manual.